HCO + H2O -> H + CO + H2O
k = 2.24E18 (T^-1) exp(-17000 cal/mol /RT) cm3/mol s
- SOURCE:
- Tsang, W., and Hampson, R.F. (1986)
J. Phys. Chem. Ref. Data 15, 1087.
- In the GRI-Mech 1.1 release, the efficiency of water was 17. In the
GRI-Mech 1.2 and 2.1 releases, the efficiency
of water is 12.
- COMMENTS:
-
Served as an optimization variable in GRI-Mech 1.1, 1.2, and 2.1 releases.
As a result of optimization round 1.1, the preexponential factor was increase by
1.41. However, in subsequent optimization rounds, 1.2 and 2.1,
the rate coefficient was returned to the original value reported above.
______________________________________________________________________
Temp delta-S delta-H kf kr Keq
(K) (cal/mol K) (kcal/mol) ----(mol,cm3,s)----- (mol/cm3)
______________________________________________________________________
300 21.1 15.7 3.08E+03 4.79E+14 6.44E-12
500 22.8 16.3 1.66E+08 9.76E+14 1.70E-07
1000 24.2 17.3 4.31E+11 1.10E+15 3.91E-04
1500 24.7 17.9 4.98E+12 1.00E+15 4.97E-03
2000 24.8 18.2 1.55E+13 9.20E+14 1.69E-02
2500 24.9 18.4 2.93E+13 8.63E+14 3.39E-02
3000 25.0 18.5 4.31E+13 8.22E+14 5.25E-02
_____________________________________________________________________